Drainage
Riprap Sizing / Channel Protection
Riprap sizing calculator for channel and outlet protection — required median stone size (D50) from design shear stress using the HEC-15 tractive-force method.
Riprap Sizing / Channel Protection
Reviewed & updated November 11, 2026Riprap — loose, durable stone placed to resist the erosive force of flowing water — is the standard protection for channel beds and banks, culvert outlets, and bridge scour-critical locations. Undersized rock shifts or washes out under design flow, while oversized rock wastes material and budget; HEC-15's tractive-force (permissible shear stress) method sizes the median stone diameter D50 directly from the shear stress the design flow exerts on the channel boundary.
This calculator applies the Shields-criterion relationship between permissible shear stress and median stone size, τp = 0.047·(γs−γw)·D50, to back-solve for the minimum D50 that resists the design shear stress τd = γw·d·S0, with a safety factor applied to the driving stress. It assumes a straight channel or outlet apron with a known design flow depth; channel bends, side slopes, and high-velocity jet flow at culvert outlets require the additional correction factors in HEC-15 Chapter 6 and 7 and should be checked before finalizing a design.
τd = γw · d · S0 (design shear stress, psf)
D50_min = SF · τd / [0.047 · (γs − γw)] (ft)
γs = SG · γw, γw = 62.4 pcf
A straight drainage channel carries flow at a design depth of 2.5 ft on a 2% slope. Using standard SG = 2.65 rock and a safety factor of 1.2, the design shear stress is 3.12 psf, and the minimum median stone size works out to 9.3 inches — rounded up to a practical nominal D50 of 12 inches, a readily available riprap gradation at most quarries.
Riprap Sizing Calculator
Tractive-force (Shields) method · imperial units