Drainage

Storm Sewer Partial-Flow Capacity

Partial-flow capacity calculator for circular storm sewer pipes — discharge, velocity, and Q/Qfull, V/Vfull ratios at any flow depth using exact circular-segment geometry.

Drainage · Open-Channel Hydraulics

Storm Sewer Partial-Flow Capacity

Reviewed & updated November 11, 2026

Storm sewers are deliberately sized to flow partially full at design conditions, maintaining a free water surface rather than surcharging under pressure. The hydraulics of a part-full circular pipe differ from full-pipe flow in a way that often surprises engineers: both discharge and velocity vary non-linearly with depth, and peak velocity actually occurs before the pipe is completely full.

This calculator computes the exact wetted area, wetted perimeter, and hydraulic radius for any flow depth using circular-segment geometry, then applies Manning's equation directly — rather than looking up an approximate ratio from a hydraulic-elements chart. At d/D = 1.0 the formulas reduce exactly to the familiar full-pipe values (A = πD²/4, R = D/4) used in this site's standard Manning's equation calculator.

Partial-Flow Geometry — Circular Pipe
θ = 2·arccos(1 − 2d/D) (central angle, radians) A = (D²/8)(θ − sinθ), P = (D/2)·θ, R = A/P Q = (1.486/n)·A·R^(2/3)·S^(1/2), V = Q/A
Reference: Chow, Open-Channel Hydraulics (1959); classical circular-segment hydraulic-elements relationships, consistent with the full-pipe Manning's equation used elsewhere on this site (reduces exactly to A = πD²/4, R = D/4 at d/D = 1).
Worked Example

A 24-inch pipe (n = 0.013) on a 0.5% slope flowing at an 18-inch depth (d/D = 0.75) has a wetted area of 2.53 ft² and hydraulic radius of 0.603 ft. That gives a discharge of 14.6 cfs at 5.77 fps — 91% of the pipe's full-flow capacity of 16.0 cfs, but 113% of its full-flow velocity, since partial flow near three-quarters depth actually moves faster than the same pipe flowing completely full.

Read the Full Guide →

Partial-Flow Capacity Calculator

Circular pipe, part-full flow · imperial units

Must be less than the pipe diameter
Example: 0.005 = 0.5%
PVC 0.010   Concrete 0.013   HDPE 0.012
Partial-Flow Results
Discharge (Q)—
Velocity (V)—
Flow Depth Ratio (d/D)—
Q / Q_full—
V / V_full—
Full-Pipe Capacity (Q_full)—
Wetted Area / Hyd. Radius—
Classical circular-segment geometry (Chow, 1959). Depths above about 0.82D risk free-surface instability and intermittent surcharging. Requires PE review.